Lindos Electronics

Tel: +44 (0)1394 380307
Fax: +44 (0)1394 385156
E-mail: info@lindos.co.uk

Lindos Electronics, Saddlemakers Lane
Melton, Woodbridge, Suffolk, IP12 1PP, UK

Home PricingProductsDownloadsArticlesTest Results DatabaseDistributors
TestItTest Results
LINDOS AUDIO SEQUENCE TEST CANFORD - 91-143 - Microphone
SOURCE MS10 V3.0
14-Nov-05 06:17 PM


FREQU RESPONSE [u] 0dB
20Hz -3.63 -19.12
31Hz -4.49 -19.50
40Hz -5.49 -19.50
50Hz -7.24 -19.50
100Hz -4.13 -18.00
315Hz +0.38 -4.37
1k0 +0.00 0.00
6k3 +0.13 +3.87
10k0 +0.13 -11.87
12k5 +4.49 -8.75
14k0 +2.38 -11.37
16k0 -3.99 -18.12
20k0 -12.24 -19.50
25k0 -18.63 -19.50
TEST LEVEL OUT 400Hz [t]
TL dB -00.78 -05.01
DELms 0000
SPEED ERROR [e]
SPD+% -00.00
NOISE ITU-468 Q-Pk REL [m]
WTD -51.57 -47.68
DIST RES 1kHz WTD REL [r]/q
-20dB -34.80 -32.67
0dB -42.61 -36.86
+8dB -41.66 -38.00
+12dB -38.67 -34.38
+15dB -35.57 -32.78
+18dB -32.52 -30.21
FREQUENCY RESPONSE [DIFF]


Appalling frequency respose, no bass! Suspect this is 91-143 sold as having speech-only response, though it was supplied as a 91-142 sold as 'truly flat response'!

Tested by comparison with Lindos MM3 mic (blue trace) at 100mm from 3" source.


Noise results are not valid (noise from power amp limiting noies floor). Actual noise is around -60dB (40dB SPL 468-wtd)