YELLOWTEC PUC D/A - PUC - PC Sound Card
LINDOS AUDIO SEQUENCE TEST YELLOWTEC PUC D/A - PUC - PC Sound Card
SOURCE MS10 V2.9 Replay only - CD2 44k AL@-18FS Noise-Shaped
14-Jan-05 11:54 AM TOLERANCE Lindos GradeA PASSED


FREQU RESP 0dB [u]
20Hz -00.62 -00.62 ±2
31Hz 00.00 00.00 ±1
40Hz 00.12 00.12 ±1
50Hz -00.12 -00.12 ±1
100Hz -00.12 00.00 ±1
315Hz 00.00 00.00 ±1
1k0 00.00 00.00 ±1
6k3 00.00 00.00 ±1
10k0 00.00 00.00 ±1
12k5 00.00 00.00 ±1
14k0 -00.12 -00.12 ±1
16k0 -00.25 -00.25 ±1
20k0 -01.62 -01.62 ±2
25k0 -20.62 -20.50
TEST LEVEL OUT [t]
0dB 00.19 00.20 ±1<1
NOISE ITU-468 REL [n]
WTD -63.16 -63.11 -60
DIST RES 1kHz WTD REL [r]/q
-20dB -41.77 -41.93 -40
0dB -61.93 -62.08 -45
+8dB -69.50 -69.53 -45
+12dB -71.44 -72.09 -45
+15dB -70.92 -70.95 -45
+18dB -65.50 -66.33 -45


Good as sound cards go, but not true 16-bit performance! The accurate output levels are very nice, but noise levels are around 4dB worse than 16-bit, even on this replay only test from a a Lindos WAV file.