Canon - 60D - Other
LINDOS AUDIO SEQUENCE TEST Canon - 60D - Other
SOURCE MS20 V1.3 Osc level -28dB
12-Jan-12 05:55 PM


FREQUENCY RESPONSE @0dB [u]
20Hz -21.00 -21.12
31Hz -14.37 -14.50
40Hz -11.87 -12.00
50Hz -9.25 -9.25
100Hz -4.00 -4.00
315Hz -0.50 -0.50
1k0 0.00 0.00
6k3 +0.12 +0.12
10k0 +0.25 +0.25
12k5 +0.25 +0.25
14k0 +0.12 +0.12
16k0 -0.12 -0.12
20k0 -1.25 -1.12
25k0 -12.87 -12.62
FREQUENCY RESPONSE [DIFF]0
LEVEL VS LEVEL [h]
TEST LEVEL OUT 1kHz [t]
TL dB 00.16 00.16
DELms
NOISE ITU-468 Q-Pk REL [n]
WTD -50.07 -50.07
DIST RES 1kHz WTD REL [r]/q
-20dB -28.35 -28.60
0dB -49.06 -48.91
+8dB -56.56 -56.80
+12dB -60.44 -60.39
+15dB -62.86 -62.78
+18dB -63.99 -63.87
PHASE DIFFERENCE R-L [z]
3k15 24.00
10k0 76.00
15k0 100.00


Level with 4k7 in series -10.7
Shorted out +0.16
Difference 10.5

Bottom graph is comparison with 5D

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!


LA100 Silver Upgrades

The LA100 silver upgrade is available to all units whatever the vintage. It adds all of the features in the latest LA100 MK3 to an older unit

Upgrading Your LA100

LA100 Testimonial

"If someone is looking for an accurate, reliable, economical, easy to use test system for audio quality test, Lindos is the answer for it.We have been using many of this unit (LA100) in our broadcast TV and FM Radio maintenance works and will continue using is for many years.

It is surely the best test gear for line, transmitter, amplifiers and other audio related equipment tests.We consider it a must have unit for out broadcast TV and FM Radio maintenance team."

Baithori Kamdi,
Broadcast Engineer,
Telecom Malaysia